MX 43 – Modular gas alarm center for up to 32 gas detectors
The MX 43 from Teledyne Oldham Simtronics is an advanced and scalable gas alarm center developed for continuous monitoring of flammable and toxic gases as well as oxygen in industrial environments.
The control panel combines analog and digital communication in a flexible system with support for up to 32 gas detectors distributed over eight communication lines. The modular design allows the system to be adapted to the needs of the installation and to be gradually expanded.
The MX 43 is available in both wall-mounted and 19-inch rack-mounted versions.
Flexible and reliable gas monitoring
The MX 43 is equipped with a large backlit graphic LCD display that provides the operator with a clear overview of current gas concentrations, alarm levels and system status. Up to 16 gas detectors can be displayed simultaneously on the display.
The control panel supports analog 4–20 mA gas detectors and compatible digital gas detectors. By combining analog and digital communication, the installation can be optimized while reducing the need for extensive wiring.
Programmable relay outputs enable the control of external safety functions such as ventilation, magnetic valves, sound and light alarms, and other process-related functions.
Features and benefits
- Continuous monitoring of up to 32 gas detectors.
- Available with 4 or 8 communication lines.
- Support for analog and digital gas detectors.
- Modular and scalable system architecture.
- Large backlit graphic LCD display.
- Simultaneous display of up to 16 gas detectors.
- Three individually programmable gas alarm levels per detector.
- Alarm for exceeding and under-measuring range.
- Five integrated programmable alarm relays.
- Separate relay for fire alarm.
- RS485 Modbus RTU communication.
- Advanced programmable alarm logic.
- Integrated alarm, fault and event log.
- USB data logging as an option.
- Possibility of integrated battery backup.
- Support for functional safety according to SIL 1.
- Wall-mounted installation or 19-inch rack installation.
Expansion possibilities
The MX 43 can be supplemented with external addressable expansion modules to expand the functionality of the central unit and create a complete gas detection system.
- Relay module: 4 or 8 programmable relay outputs.
- Analog input module: 8 analog inputs for example for gas and flame detectors.
- Digital input module: 16 logic inputs for example emergency stop, fire alarm and external status signals.
- Analog output module: 4 analog 4–20 mA outputs for transferring measurement values to external systems.
The expansion modules can be placed close to detectors and external security functions, which simplifies installation and reduces installation costs.
Advanced configuration and alarm logic
With the COM 43 configuration software, the alarm levels, relay functions, time delays, and alarm logic of the system can be adapted to the specific safety requirements of the operation.
The software supports logical functions such as AND, OR, NOR, NAND, and VOTING. This enables advanced alarm combinations where multiple gas detectors can together activate a common safety function.
MX 43 can also be integrated with parent PLC, SCADA and building automation systems.
Event log and data storage
The control panel has an integrated event log with the capacity to store:
- 512 alarm events.
- 512 incidents.
- 512 system events.
With USB data logging as an option, continuous measurement values can be stored with a configurable logging interval ranging from 2 seconds to 15 minutes. A 4 GB USB memory card enables more than two years of data storage in most system configurations.
The USB function can also be used for backing up and restoring system configuration and firmware.
Technical specifications
| Parameter | Technical specification |
|---|---|
| Manufacturers | Teledyne Oldham Simtronics |
| Model | MX 43 |
| Product type | Stationary gas alarm control panel |
| Number of gas detectors | Up to 32 |
| Communication lines | 4 or 8 |
| Capacity, 4-line version | Up to 16 detectors |
| Capacity, 8-line version | Up to 32 detectors |
| Direct analog inputs | Up to 8 × 4–20 mA |
| Digital input lines | RS485, manufacturer-specific protocol |
| Display | Backlit graphic LCD |
| Simultaneous display | Up to 16 gas detectors |
| Gas alarm levels | 3 per detector |
| Integrated Relays | 5 alarm relays + 1 error relay |
| Relay capacity | 2 A / 250 VAC, inductive load |
| External communication | RS485 Modbus RTU |
| Configuration software | COM 43 |
| USB Data Logging | Optional, 4 GB |
| Logging interval | 2 seconds to 15 minutes |
| Battery backup | 0.6 Ah, optional |
| Supply voltage | 100–240 VAC or 21–28 VDC |
| Maximum power | 112 W |
| Operating temperature | −20 to +50 °C |
| Humidity | 5–95 % RH |
| Enclosure class, wall mounting | IP55 |
| Enclosure class, rack mounting | IP31 |
| Dimensions, wall mounting | 370 × 299 × 109 mm |
| Dimensions, rack mounting | 482.8 × 177 × 192.5 mm |
| Rack size | 19 inch, 4U |
| Functional safety | SIL 1 capacity according to EN 50271:2010 |
| Metrological performance | EN 60079-29-1 |
Areas of application
- Industrial and process plants
- Chemical and petrochemical industry
- Oil and gas industry
- Hydrogen facilities
- Battery charging stations
- Power and heating plants
- Refrigeration and freezing equipment
- Water and treatment plants
- The food industry
- Gas storage facilities and gas distribution centers
- Marina installations
- Garages and parking facilities
Documentation
Product sheet MX43 (PDF, English)






