ExTox ET-1D – Compact 1-channel gas alarm center
ET-1D from ExTox is a compact and user-friendly gas alarm center developed for continuous monitoring of flammable and toxic gases as well as oxygen.
The central unit is designed for connecting a gas detector and offers individually configurable alarm levels, programmable alarm functions, and communication with higher-level control systems.
The compact wall-mounted design makes the ET-1D a cost-effective solution for smaller gas detection systems in industry, buildings, and process plants.
Reliable and continuous gas monitoring
The ET-1D is equipped with a backlit four-digit display that displays the current gas concentration, alarm messages and system status. The gas concentration is also presented graphically in the form of a bar graph.
The control panel has two individually adjustable alarm levels as well as separate LED indicators for operation, gas alarm and system faults.
Through four integrated switching relay outputs, external functions such as ventilation, sound and light alarms, and other safety functions can be activated.
All settings can be configured directly from the central unit’s front panel via four function buttons, which simplifies installation, commissioning and maintenance.
Features and benefits
- Continuous monitoring of a gas detector.
- Support for flammable and toxic gases as well as oxygen.
- Analog 4–20 mA input.
- Two individually adjustable alarm levels.
- Configurable self-activating alarm function.
- Backlit four-line display.
- Graphical presentation of gas concentration.
- LED indication for operation, alarm and faults.
- Four integrated switching relay outputs.
- RS232/RS485 communication.
- Alarm blocking during servicing and maintenance.
- Separate notification of acoustic alarm.
- Compact wall-mounted design.
- Enclosure class IP54.
- Simple configuration directly from the front panel.
System integration and alarm functions
The ET-1D can be used as a standalone gas alarm center or integrated with an upstream process and monitoring system via RS232/RS485.
The central’s separate relay functions for alarm level 1, alarm level 2, system failure and acoustic alarm enable flexible adaptation to the installation’s safety requirements.
During servicing and maintenance, the alarm functions may be temporarily blocked to prevent unwanted activation of external safety functions.
Technical specifications
| Parameter | Technical specification |
|---|---|
| Manufacturers | ExTox |
| Model | ET-1D |
| SKU | 303000 |
| Product type | Stationary gas alarm control panel |
| Number of gas detectors | 1 |
| Analog input | 4–20 mA |
| Signal processing | Microprocessor with A/D converter |
| Display | Backlit four-line display |
| Alarm levels | 2 |
| Relay outputs | 4 alternating contacts |
| Relay functions | Alarm 1, alarm 2, fall alarm and acoustic alarm |
| Relay capacity | 230 V / 200 mA |
| Communication | RS232 / RS485 |
| Supply voltage | 230 VAC |
| Maximum power consumption | 0.08 A |
| Maximum power consumption | 18 W |
| Operating temperature | −10 to +40 °C |
| Storage temperature | −25 to +60 °C |
| Enclosure material | ABS plastic |
| Protection class | IP54 |
| Dimensions (B × H × D) | 160 × 194 × 90 mm |
| Cable penetrations | 1 × M20 and 5 × M16 |
| Mounting | Wall mounting |
Areas of application
- Industrial and process plants
- Heating plants and power stations
- Laboratories
- Gas storage facilities and gas distribution centers
- Battery charging stations
- Refrigeration and freezing equipment
- Water and treatment plants
- Machine rooms and technical spaces
- Monitoring of oxygen content
- Monitoring of individual risk areas
Documentation
Product sheet ET-1D (PDF, English)