Nitrogen oxides, NOx, are a common emission parameter in combustion and industrial processes. For businesses that need to control, document, or reduce their emissions, therefore measurement of NOx an important part of emissions monitoring.
The measurement can be done periodically or continuously and with different analytical principles depending on the facility, the concentration level and the requirements that apply. An established reference method for measuring NOx from stationary emission sources is chemical luminescence according to SS-EN 14792.
At PPM Industrial we work with instruments and systems for emission measurement where NOx can be one of several components that need to be analyzed.
What is NOx?
NOx is a collective name for nitrogen oxides. In emission measurement, it primarily refers to:
- Nitrous oxide, NO
- Nitrogen dioxide, NO₂.
In the EU regulations for medium-sized combustion plants, NOx is defined as the sum of NO and NO₂, expressed as NO₂. See EU Directive 2015/2193 at EUR-Lex
Nitric oxides are formed primarily during combustion processes where high temperatures allow nitrogen and oxygen to react. Even nitrogen present in the fuel can contribute to emissions.
The Swedish Environmental Protection Agency describes that the largest emissions of nitrogen oxides occur during combustion processes. Energy and industrial activities, along with transport, are important sources of emissions. The Swedish Environmental Protection Agency – Facts about nitrogen oxides in the air
Why are NOx emissions measured?
NOx measurement can fulfill several different functions.
In some plants, the measurement is carried out to verify that emission conditions or statutory limits are being met. In other cases, the measurement data is also used to monitor the combustion process, evaluate purification equipment, or optimize operations.
Common purposes are to:
- documenting emissions to air
- check emission limits
- follow changes in the process
- evaluate the effect of NOx reduction measures
- check the combustion
- calculate the emitted quantities
- create the basis for environmental reporting.
NOx affects both human health and the environment. Nitrogen oxides contribute, among other things, to the formation of ground-level ozone, as well as to acidification and overfertilization of soil and water. The Swedish Environmental Protection Agency also describes that nitrogen dioxide can affect the airways and that both short- and long-term exposure is linked to negative health effects. Read the Swedish Environment Agency's compilation on nitrogen oxides
Where is the need for NOx measurement?
Measurement of NOx is relevant in many operations where combustion takes place.
This could for example be about:
- cogeneration plant
- boiler central units
- district heating systems
- waste incineration
- gas turbines
- Stationary combustion engines
- process industry
- mass and paper industry
- refineries
- metal industry
- cement and mineral industry.
However, the requirements differ between different types of operations and plant sizes. Therefore, which measurements are required must always be assessed based on the environmental permit of the plant in question and the applicable regulations.
How is NOx measured in flue gases?
There are several techniques for measuring nitrogen oxides.
For regulatory measurements, it is particularly important to distinguish between a method that can measure NO and a method that can determine the total amount of NOx.
A significant portion of the NOx in flue gases normally consists of NO. However, since emissions are often reported as the sum of NO and NO₂, a measurement solution is needed that can determine both components or convert NO₂ so that the total content can be calculated.
Chemical luminescence – reference method for NOx
Chemical luminescence is a well-established method for measuring NO and NOx.
The principle is based on a reaction between nitrogen monoxide and ozone. When NO reacts with ozone, excited nitrogen dioxide is formed, which emits light when the molecule returns to a lower energy state. The light intensity can be measured and related to the concentration of NO.
To measure total NOx, NO₂ can first be converted to NO. The analyzer can then measure the sum of the original NO and the NO formed from NO₂.
The current Swedish standard SS-EN 14792:2017 Describes chemical luminescence as the standard reference method for determining the mass concentration of nitrogen oxides in emissions from stationary sources. The standard includes, among other things, sampling, gas preparation, and the analyzer itself. SS-EN 14792:2017 at SIS
The standard is used, among other things, for periodic emissions monitoring, as well as for the calibration and control of permanently installed automatic measurement systems.
NO, NO₂ and the importance of NOx conversion
In chemiluminescence, NO is measured directly.
To determine NOx, NO₂ usually first needs to be converted to NO using a converter. The result of the NOx measurement can then be compared with the NO value to determine the proportion of NO₂.
This requires that the converter has sufficient efficiency and that the system is properly controlled.
PPM’s technical documentation for the California Analytical 700 LX describes, for example, an NOx analyzer where the sample in the NOx mode is passed through an NO₂-to-NO converter before the analysis is performed using chemiluminescence. The instrument can operate with NO, NOx, or separated NO/NO₂/NOx. See product sheet for the 700 LX Series NOx Analyzer from PPM Industrial
Other measurement principles for NO and NOx
Chemical luminescence is not the only technique that can be used.
Depending on the application, the following methods may be used, among others:
NDIR
Non-dispersive infrared measurement, NDIR, is based on the fact that certain gases absorb infrared radiation at specific wavelengths.
NO can be analyzed using NDIR in some instruments. If total NOx is to be measured, a converter is usually required to convert NO₂ to NO before the analysis.
FTIR
FTIR, Fourier Transform Infrared Spectroscopy, can be used when several components need to be analyzed simultaneously.
The technology could be interesting, for example, in the case of complex industrial emissions where NO and NO₂ need to be analyzed together with gases such as CO, CO₂, SO₂, HCl, NH₃ or various organic compounds.
Electrochemical sensors
Electrochemical sensors are also used for measuring NO and NO₂, primarily in portable measurement equipment and gas detection.
The appropriate technology therefore depends on whether the measurement is to be used for, for example, process control, occupational health and safety, indicative measurement or regulatory emissions control.
PPM has several types of gas analysis equipment for stationary and portable gas analysis.
Periodic or continuous NOx measurement?
NOx can be measured both periodically and continuously.
Periodic NOx measurement
In periodic measurement, measurement equipment is used for a limited period to determine the emission level under representative operating conditions.
The method is used for example for:
- periodic emission tests
- comparative measurements
- verification of automatic measurement systems
- control after process changes.
Continuous NOx measurement
In continuous measurement, an automatic measurement system is used that monitors the NOx concentration during the operation of the plant.
It provides significantly more information about variations over time and can be used for both emissions control and process monitoring.
For those who want to delve into how such systems are built, PPM has an article on the subject. continuous emission measurement, where the entire measurement chain from sampling to analysis and data collection is handled.
Rules for medium-sized incineration plants
The EU directive on medium combustion plants covers combustion plants with an installed rated output of at least 1 MW but less than 50 MW. The directive regulates, among other things, emissions of NOx, SO₂ and dust. Directive (EU) 2015/2193 at EUR-Lex
According to Annex III of the directive, periodic measurements should normally be carried out at least:
- Every three years for installations of 1–20 MW
- every year for installations exceeding 20 MW.
The directive also gives Member States the option to require continuous measurement. If continuous automatic measurement systems are used, these must be checked by parallel measurements using reference methods at least once a year according to the directive.
However, the requirements that actually apply to a Swedish facility need to be checked against Swedish legislation, the business’s permit, and any specific conditions.
The Swedish nitrogen oxide tax
Sweden also has a special financial instrument for emissions of nitrogen oxides from certain energy-producing combustion plants: Nitrogen oxide fee, often called the NOx fee.
According to the Swedish Environmental Protection Agency, the purpose is to create economic incentives to reduce NOx emissions from energy production. The Swedish Environmental Protection Agency – The nitrogen oxide fee
The underlying law is Act (1990:613) on an environmental fee on emissions of nitrogen oxides in energy production.
The law covers production units that reach an energy production of at least 25 GWh during the reporting period. According to current law, the fee is 50 kronor per fully kilogram of emitted nitrogen oxides, calculated as nitrogen dioxide. Read the relevant legal text at the Swedish Parliament
For facilities that are part of the system, there are specific regulations regarding how emissions are determined.
NFS 2016:13 and requirements for the measurement equipment
The Swedish Environmental Protection Agency has issued NFS 2016:13, Regulations concerning measurement equipment for determining the environmental fee on emissions of nitrogen oxides in energy production.
The Swedish Environmental Protection Agency describes that the regulations include requirements for, among other things:
- measurement instruments for NOx
- determination of flue gas flow
- comparative measurements.
On the same page, the Swedish Environmental Protection Agency also refers to SS-EN 14792 as the reference method for NOx measurement and SS-EN 14181 for quality assurance of automatic measurement systems in the activities where that standard applies.
Quality assurance of continuous NOx measurements
A continuous measurement value needs to be reliable throughout the entire system's operation.
The analyzer can be affected by, among other things:
- Zero-point operation
- achievement
- changed gas flow
- temperature
- pressure
- moisture
- Interfering gases
- soiling
- changed conversion efficiency.
Therefore, control and quality assurance are an important part of continuous NOx measurement.
SS-EN 14181 deals with quality assurance of automatic measurement systems. The Swedish Environmental Protection Agency refers to the standard for, among other things, large incineration plants and plants that burn waste. Information from the Swedish Environmental Protection Agency about standards for automatic measurement systems
In these contexts, the terms QAL1, QAL2, QAL3 and AST are used for different parts of quality assurance.
Sampling and gas preparation affect the measurement result
An NOx analyzer can only provide an accurate result if the gas sample reaching the instrument is representative.
In extractive measurement, a portion of the flue gas is extracted and transported to the analyzer.
Depending on the process, the system may need to include:
- sampling probe
- heated test lead
- filter
- pump
- cooler
- condensing technology
- flow control.
The choice of gas preparation must be adapted to the measurement method.
It is important, for example, to avoid NO₂ being lost in the sampling system or for condensation and particulate matter to affect the analysis.
SS-EN 14792 therefore does not only cover the analytical instrument but also sampling and gas preparation as part of the reference method. See the scope of SS-EN 14792 at SIS
Concentration is not the same thing as total emissions
An NOx analyzer primarily measures the concentration of the gas.
The result can be stated for example in:
ppm
or
mg/Nm³.
Furthermore, for emission limits the value often needs to be specified under specific reference conditions, such as dry gas and a specified oxygen content.
SS-EN 14792 describes that the NOx limit values in relevant EU regulations are expressed as mg NO₂/m³ at specified reference conditions.
If the total amount of emitted NOx is to be determined, the flue gas flow must also be taken into account.
Therefore, a relatively low concentration can still result in a large total emission if the gas flow is high.
NOx measurement as a tool for process optimization
NOx measurement does not only need to be used for environmental reporting.
Continuous measurements can also provide information about what happens in the combustion process.
The formation of NOx is influenced by factors such as temperature, oxygen availability, fuel, and the duration of time spent in the combustion zone. Changes in NOx can therefore provide information about how different operating modes affect emissions.
By analyzing NOx together with, for example:
- O₂
- CO
- CO₂
it is possible to create a broader picture of how combustion works.
A change that reduces NOx, for example, is not automatically positive if it simultaneously leads to a significant increase in CO emissions or a deterioration in efficiency. The process therefore needs to be assessed as a whole.
The EU Commission’s BREF document for large combustion plants describes emissions monitoring as a tool for both compliance with emission limits and for monitoring the combustion process and purification systems. EU Commission’s BREF for Large Combustion Plants
What should be considered when choosing an NOx analyzer?
The choice of instrument should be based on the application and not solely on the type of gas specified in the analyzer specifications.
Important questions include:
- Should NO, NO₂ or total NOx be measured?
- What concentration range is expected?
- Should the measurement be continuous or periodic?
- Are there high levels of moisture or particles present?
- What other gases are present in the sample?
- Is heated sampling required?
- How quickly does the instrument need to react?
- Are there regulatory requirements for the measurement method?
- How should the analyzer be calibrated?
- Is redundancy or automatic validation required?
- How should measurement data be stored and reported?
PPM Industrial works with stationary gas analysis equipment and complete solutions where the analysis instruments, sampling and gas preparation can be adapted to the process.
Calibration and servicing of NOx systems
The measurement system needs to be able to be checked against known references.
During calibration, normally certified gas mixtures with known concentrations are used to control the zero point and span.
The frequency of inspections needs to be carried out depends, among other things, on the instrument, the application and the requirements that apply to the measurement.
Regular monitoring makes it possible to detect malfunctions before they lead to incorrect reporting or control of the process.
PPM offers both equipment and service and calibration of gas instruments.
Reliable NOx measurement requires a complete measurement chain
Measuring NOx is about more than installing an NOx analyzer.
To obtain reliable measurement values, the entire chain needs to function:
Representative sampling → proper gas transport → customized gas preparation → appropriate analytical method → calibration → quality assurance → data processing.
Which solution is appropriate depends on the process, the concentrations to be measured, and what the measurement data is to be used for.
At PPM Industrial we work with equipment and customized solutions for gas analysis and emissions measurement. We can help select the analysis principle, sampling equipment, and gas preparation based on the current process and the requirements for the measurement.