{"id":5848,"date":"2023-11-28T10:46:17","date_gmt":"2023-11-28T09:46:17","guid":{"rendered":"https:\/\/www.ppmindustrial.com\/?post_type=product&#038;p=5848"},"modified":"2026-11-25T12:42:40","modified_gmt":"2026-11-25T11:42:40","slug":"extox-et-1d-gas-alarm-control-panel","status":"publish","type":"product","link":"https:\/\/www.ppmindustrial.com\/en\/produkter\/stationar-utrustning\/centralenheter\/gaslarmcentral-extox-et-1d\/","title":{"rendered":"Gas alarm center ExTox ET-1D"},"content":{"rendered":"<div class=\"product\"><div class=\"product\"><h1>ExTox ET-1D \u2013 Compact 1-channel gas alarm center<\/h1>\n<p>ET-1D from ExTox is a compact and user-friendly gas alarm center developed for continuous monitoring of flammable and toxic gases as well as oxygen.<\/p>\n<p>The central unit is designed for connecting a gas detector and offers individually configurable alarm levels, programmable alarm functions, and communication with higher-level control systems.<\/p>\n<p>The compact wall-mounted design makes the ET-1D a cost-effective solution for smaller gas detection systems in industry, buildings, and process plants.<\/p>\n<h2><\/h2>\n<h2>Reliable and continuous gas monitoring<\/h2>\n<p>The ET-1D is equipped with a backlit four-digit display that displays the current gas concentration, alarm messages and system status. The gas concentration is also presented graphically in the form of a bar graph.<\/p>\n<p>The control panel has two individually adjustable alarm levels as well as separate LED indicators for operation, gas alarm and system faults.<\/p>\n<p>Through four integrated switching relay outputs, external functions such as ventilation, sound and light alarms, and other safety functions can be activated.<\/p>\n<p>All settings can be configured directly from the central unit\u2019s front panel via four function buttons, which simplifies installation, commissioning and maintenance.<\/p>\n<h2><\/h2>\n<h2>Features and benefits<\/h2>\n<ul>\n<li>Continuous monitoring of a gas detector.<\/li>\n<li>Support for flammable and toxic gases as well as oxygen.<\/li>\n<li>Analog 4\u201320 mA input.<\/li>\n<li>Two individually adjustable alarm levels.<\/li>\n<li>Configurable self-activating alarm function.<\/li>\n<li>Backlit four-line display.<\/li>\n<li>Graphical presentation of gas concentration.<\/li>\n<li>LED indication for operation, alarm and faults.<\/li>\n<li>Four integrated switching relay outputs.<\/li>\n<li>RS232\/RS485 communication.<\/li>\n<li>Alarm blocking during servicing and maintenance.<\/li>\n<li>Separate notification of acoustic alarm.<\/li>\n<li>Compact wall-mounted design.<\/li>\n<li>Enclosure class IP54.<\/li>\n<li>Simple configuration directly from the front panel.<\/li>\n<\/ul>\n<h2><\/h2>\n<h2>System integration and alarm functions<\/h2>\n<p>The ET-1D can be used as a standalone gas alarm center or integrated with an upstream process and monitoring system via RS232\/RS485.<\/p>\n<p>The central\u2019s separate relay functions for alarm level 1, alarm level 2, system failure and acoustic alarm enable flexible adaptation to the installation\u2019s safety requirements.<\/p>\n<p>During servicing and maintenance, the alarm functions may be temporarily blocked to prevent unwanted activation of external safety functions.<\/p>\n<h2><\/h2>\n<h2>Technical specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Parameter<\/th>\n<th>Technical specification<\/th>\n<\/tr>\n<tr>\n<td>Manufacturers<\/td>\n<td>ExTox<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>ET-1D<\/td>\n<\/tr>\n<tr>\n<td>SKU<\/td>\n<td>303000<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Stationary gas alarm control panel<\/td>\n<\/tr>\n<tr>\n<td>Number of gas detectors<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Analog input<\/td>\n<td>4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<td>Signal processing<\/td>\n<td>Microprocessor with A\/D converter<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Backlit four-line display<\/td>\n<\/tr>\n<tr>\n<td>Alarm levels<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Relay outputs<\/td>\n<td>4 alternating contacts<\/td>\n<\/tr>\n<tr>\n<td>Relay functions<\/td>\n<td>Alarm 1, alarm 2, fall alarm and acoustic alarm<\/td>\n<\/tr>\n<tr>\n<td>Relay capacity<\/td>\n<td>230 V \/ 200 mA<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>RS232 \/ RS485<\/td>\n<\/tr>\n<tr>\n<td>Supply voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Maximum power consumption<\/td>\n<td>0.08 A<\/td>\n<\/tr>\n<tr>\n<td>Maximum power consumption<\/td>\n<td>18 W<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221210 to +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>\u221225 to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Enclosure material<\/td>\n<td>ABS plastic<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td>IP54<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (B \u00d7 H \u00d7 D)<\/td>\n<td>160 \u00d7 194 \u00d7 90 mm<\/td>\n<\/tr>\n<tr>\n<td>Cable penetrations<\/td>\n<td>1 \u00d7 M20 and 5 \u00d7 M16<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Wall mounting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2>Areas of application<\/h2>\n<ul>\n<li>Industrial and process plants<\/li>\n<li>Heating plants and power stations<\/li>\n<li>Laboratories<\/li>\n<li>Gas storage facilities and gas distribution centers<\/li>\n<li>Battery charging stations<\/li>\n<li>Refrigeration and freezing equipment<\/li>\n<li>Water and treatment plants<\/li>\n<li>Machine rooms and technical spaces<\/li>\n<li>Monitoring of oxygen content<\/li>\n<li>Monitoring of individual risk areas<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>Documentation<\/strong><\/h2>\n<p><a href=\"https:\/\/www.ppmindustrial.com\/wp-content\/uploads\/2023\/12\/ET-1D_E.pdf\"><strong>Product sheet ET-1D (PDF, English)<\/strong><\/a><\/p>\n<p>&nbsp;<\/p>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<h2 data-pm-slice=\"1 1 []\">Simple and efficient stationary gas detection<\/h2>\n<p>The ET-1D combines continuous gas monitoring, flexible alarm management, and easy operation into a compact gas alarm center. The system is particularly suitable for installations where a single measurement point needs to be monitored to protect personnel, equipment, and processes.<\/p>","protected":false},"featured_media":9937,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[169,159],"product_tag":[],"class_list":["post-5848","product","type-product","status-publish","has-post-thumbnail","product_cat-centralenheter","product_cat-stationar-utrustning","desktop-align-center","tablet-align-center","mobile-align-center","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/product\/5848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/media\/9937"}],"wp:attachment":[{"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/media?parent=5848"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/product_brand?post=5848"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/product_cat?post=5848"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.ppmindustrial.com\/en\/wp-json\/wp\/v2\/product_tag?post=5848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}